11.4. Supported Devices

This section lists the device types, systems and models the current gateway version can connect to. ✓ means supported and ready to configure; ◐ means in development — the protocol is covered by the communication library the gateway uses, but the integration is unfinished, so ask the vendor about the schedule before relying on it.

The machine type, system and model are chosen in 3.3.1.1. General Settings; the options there match the tables below.

Which data and file-transfer interfaces each system and model supports is listed interface by interface in 11.5. Interface Support.

System Models State
Bosunman BSK Series Serial over Ethernet, BSK Series Ethernet, DF Series Serial over Ethernet, DF Series Ethernet ✓
Brother TC Series, S Series, A00 Series Serial over Ethernet ✓
Citizen Mitsubishi ✓
Delta General ✓
Dmg Mori 730BM, 840D, OPC UA ✓
Fagor 8035M, 8035T, 8040M, 8040T, 8055M, 8055T, 8060L, 8060M, 8060T, 8065M, 8065T, 8070L, 8070M, 8070T ✓
Fanuc 0i-B, 0i-C, 15i, 16i, 16i-W, 18i, 18i-W, 21i, Power Mate i-D, Power Mate i-H, 0i-D, 0i-F, 30i, 31i, 32i, 35i, Power Motion i-A ✓
Gsk 980, 988, 25i, Ethernet, Serial over Ethernet, 986 V4.15 ✓
Haas General, Serial over Ethernet, MT-CONNECT ✓
Heidenhain TNC640, TNC640 DNC, iTNC530 DNC ✓
Hnc 1.26.02, 1.24 ✓
IO Module ADVANTECH ADAM-6000, USR IO424T ✓
Jingdiao JD50 ✓
Kede GNC62 ✓
Knd V4.3.00b, V5.1.00c ✓
Lanhao General ✓
Lnc General ✓
Lynuc General ✓
Makino General ✓
Mazak MT-CONNECT, 640, Matrix, Smart, Smooth ✓
Mitsubishi C64, M70/M700 L Series, M70/M700 M Series, M80/M800 L Series, M80/M800 M Series ✓
Okuma P200L, P200M, P300L, P300M, P300S(LP), P300S(MP) ✓
Rexroth OPC UA ✓
Siemens 802D, 808D, 828D, 840D sl, ONE, OPC UA, 810D(winXP), 810D(winNT), 840D(winXP), 840D(winNT) ✓
Syntec General ✓
Mock General ✓
System Models State
Hans General, OPC UA ✓
Mock General ✓
System Models State
ABB RobotWare 6.0 ✓
Fanuc General ✓
Knd General ✓
Kuka Controller-Side Proxy ✓
Mock General ✓
Efort ER7BC10 ◐
Estun General ◐
Hyundai General ◐
Yamaha RCX ◐
Yaskawa YRC1000, YRC High-speed Ethernet ◐
System Models State
Standard Protocols Modbus TCP, Modbus RTU, Modbus ASCII over TCP, Modbus RTU over TCP, OPC UA ✓
IO Module ADVANTECH ADAM-6000, USR IO424T ✓
Jingtuo JTE-800 ✓
Zhenhuaxing VCTA-Z5ML ✓
Allen-Bradley 1756, 1769, 1783, Micro800 Series, SLC Series, Others ✓
Delta AS Series, DVP Series ✓
Keyence KV700, KV300, KV Nano Series, Others ✓
Melsec Q Series, L Series, Ethernet Module QJ71E71, Ethernet Module QJ71EIP71, A Series, R Series, FX2N Series, FX3G Series, FX3S Series, FX3U Series, FX5U Series, Others ✓
Omron NJ Series, NX Series, NY Series, Others ✓
Panasonic General ✓
Simatic S7-200, S7-200 Smart, S7-300, S7-400, S7-1200, S7-1500, Others ✓
Yongwei General, General over TCP ✓
Mock General ✓
Beckhoff CX Series, BC/BX Series (Ethernet models) ✓
Cimon All models ◐
Fatek Programming port (serial, serial over Ethernet) ◐
Fuji SPB, SPH ◐
GE SRTP ◐
Inovance Easy Series, H5U Series, H3U/S Series, H1U/S Series, EVO Series, AM Series, AC Series, Others ✓
LSIS XGB (Cnet, CPU, Fast Enet) ◐
MegMeet MC80, MC100, MC200, MC200E, MC280 ◐
Toyopuc Computer Link (2PORT-EFR module) ◐
Vigor VS Series ◐
Xinje XC, XD, XL, XG, XDQ, XLQ, XS ✓
Yaskawa Memobus ◐
Yokogawa Link ◐
  • Models of the same brand do not collect the same data. Fagor [8060, 8065, 8070 Series], for example, supports neither file transfer nor tool data, while [8035, 8040, 8055 Series] supports both. Check the exact model against 11.5. Interface Support before choosing a system.
  • Some systems are rebadged controls. Citizen uses a Mitsubishi control, and Makino and Dmg Mori [840D] use Fanuc and Siemens controls respectively, so they collect the same data as the underlying system.
  • IO Module appears under both CNC machine tools and PLCs, for machines that offer no communication interface at all: an external IO module samples signal lamps, cycle-start signals and similar digital inputs, and the gateway derives machine status from them.
  • Mock connects to no real device. It exists so gateway configuration and upstream integration can be verified without a machine — see 10. Mock Machine Testing.
  • Whether data can actually be collected also depends on the optional functions enabled on the machine (Fanuc DNC permission, Heidenhain Option 18 and the like), on correct network and port settings, and on the tasks included in the gateway licence — see 3.3.1.2. Task Settings.