11.5. Interface Support

Controls differ widely in what they expose, so an interface is not available on every device. This section lists, interface by interface, which systems and models support it. It is the reference for deciding whether a given machine can supply a given value.

It applies to every transport: the HTTP APIs, the MQTT RPC commands and the collection tasks all use the same interfaces and have the same support.

Key:

Mark Meaning
Supported: the current version can read (or write) this data on this system and model.
In development: the protocol is covered by the communication library the gateway uses, but the integration is unfinished. The marks show what will be available once it is.
Not supported: the control itself does not offer the interface, so the gateway cannot support it.
Interface Data Table Section
readCNCStatus Status Basic Data 5.5.1.2
readAlarm Alarms Basic Data 5.5.1.1
readCount Part Count Basic Data 5.5.1.4
readCurrentToolNumber Current Tool Basic Data 5.5.1.5
readTimeData Time Data Basic Data 5.5.1.22
readProgramInfo Program Info Basic Data 5.5.1.19
readProgramBlock Program Block Program and Position 5.5.1.18
readPosition Position Program and Position 5.5.1.17
readCurrentProgram Running File Program and Position 5.6.4
readLog Machine Log Program and Position 5.5.1.11
readFeedAndSpindle Feed and Spindle Feed, Load and Energy 5.5.1.8
readFeed Feed Feed, Load and Energy 5.5.1.7
readLoad Load Feed, Load and Energy 5.5.1.10
readEnergyConsum Energy Feed, Load and Energy 5.5.1.6
readLaserPower Laser Power Feed, Load and Energy 5.5.1.9
readToolLife Tool Life Tooling and PLC Data 5.5.1.23
readOffsetData Read Offsets Tooling and PLC Data 5.5.1.14
writeOffsetData Write Offsets Tooling and PLC Data 5.5.1.16
readPlcData Read PLC Data Tooling and PLC Data 5.5.1.20
writePlcData Write PLC Data Tooling and PLC Data 5.5.1.21
readProgramList List Files File Transfer 5.6.1
receiveFileStream Receive File File Transfer 5.6.2
sendFileStream Send File File Transfer 5.6.5
deleteFile Delete File File Transfer 5.6.8
createDir Create Directory Directories and Program Selection 5.6.11
deleteDir Delete Directory Directories and Program Selection 5.6.12
selectProgram Select Program Directories and Program Selection 5.6.14
lockFileByRange Lock Editing Directories and Program Selection 5.6.10

readCNCStatusDetails and readCNCCommonStatus derive from readCNCStatus, readToolLifeDetails derives from readToolLife, and each batchRead* interface derives from its single-machine counterpart. Their support is identical to the interface they derive from, so they are not listed separately.

System [Model] readCNCStatus readAlarm readCount readCurrentToolNumber readTimeData readProgramInfo
Bosunman[BSK Series]
Bosunman[DF Series]
Brother[TC Series]
Brother[S Series]
Brother[A00 Series Serial over Ethernet]
Citizen[Mitsubishi]
Delta[General]
Dmg Mori[730BM]
Dmg Mori[840D]
Dmg Mori[OPC UA]
Fagor[8035M, 8035T, 8040M, 8040T]
Fagor[8055M, 8055T]
Fagor[8060L, 8060M, 8060T, 8065M, 8065T, 8070L, 8070M, 8070T]
Fanuc[0i-B, 0i-C, 15i, 16i, 16i-W, 18i, 18i-W, 21i, Power Mate i-D, Power Mate i-H]
Fanuc[0i-D, 0i-F, 30i, 31i, 32i, 35i, Power Motion i-A]
Gsk[980, 988]
Gsk[25i]
Gsk[Ethernet, Serial over Ethernet]
Gsk[986 V4.15]
Haas[General, Serial]
Haas[MT-CONNECT]
Heidenhain[TNC640, TNC640 DNC]
Heidenhain[iTNC530 DNC]
Hnc[1.26.02]
Hnc[1.24]
IO Module[ADVANTECH ADAM-6000]
IO Module[USR IO424T]
Jingdiao[JD50]
Kede[GNC62]
Knd[All models]
Lanhao[General]
Lnc[General]
Lynuc[General]
Makino[General]
Mazak[MT-CONNECT]
Mazak[640, Matrix]
Mazak[Smart, Smooth]
Mitsubishi[All models]
Okuma[All models]
Rexroth[OPC UA]
Siemens[802D, 808D, 828D, 840D sl, ONE, OPC UA]
Siemens[810D(winXP), 810D(winNT), 840D(winXP), 840D(winNT)]
Syntec[General]
Mock[General]

✓ Supported; ◐ In development; ✗ Not supported

System [Model] readProgramBlock readPosition readCurrentProgram readLog
Bosunman[BSK Series]
Bosunman[DF Series]
Brother[TC Series]
Brother[S Series]
Brother[A00 Series Serial over Ethernet]
Citizen[Mitsubishi]
Delta[General]
Dmg Mori[730BM]
Dmg Mori[840D]
Dmg Mori[OPC UA]
Fagor[8035M, 8035T, 8040M, 8040T]
Fagor[8055M, 8055T]
Fagor[8060L, 8060M, 8060T, 8065M, 8065T, 8070L, 8070M, 8070T]
Fanuc[0i-B, 0i-C, 15i, 16i, 16i-W, 18i, 18i-W, 21i, Power Mate i-D, Power Mate i-H]
Fanuc[0i-D, 0i-F, 30i, 31i, 32i, 35i, Power Motion i-A]
Gsk[980, 988]
Gsk[25i]
Gsk[Ethernet, Serial over Ethernet]
Gsk[986 V4.15]
Haas[General, Serial]
Haas[MT-CONNECT]
Heidenhain[TNC640, TNC640 DNC]
Heidenhain[iTNC530 DNC]
Hnc[1.26.02]
Hnc[1.24]
IO Module[ADVANTECH ADAM-6000]
IO Module[USR IO424T]
Jingdiao[JD50]
Kede[GNC62]
Knd[All models]
Lanhao[General]
Lnc[General]
Lynuc[General]
Makino[General]
Mazak[MT-CONNECT]
Mazak[640, Matrix]
Mazak[Smart, Smooth]
Mitsubishi[All models]
Okuma[All models]
Rexroth[OPC UA]
Siemens[802D, 808D, 828D, 840D sl, ONE, OPC UA]
Siemens[810D(winXP), 810D(winNT), 840D(winXP), 840D(winNT)]
Syntec[General]
Mock[General]

✓ Supported; ◐ In development; ✗ Not supported

System [Model] readFeedAndSpindle readFeed readLoad readEnergyConsum
Bosunman[BSK Series]
Bosunman[DF Series]
Brother[TC Series]
Brother[S Series]
Brother[A00 Series Serial over Ethernet]
Citizen[Mitsubishi]
Delta[General]
Dmg Mori[730BM]
Dmg Mori[840D]
Dmg Mori[OPC UA]
Fagor[8035M, 8035T, 8040M, 8040T]
Fagor[8055M, 8055T]
Fagor[8060L, 8060M, 8060T, 8065M, 8065T, 8070L, 8070M, 8070T]
Fanuc[0i-B, 0i-C, 15i, 16i, 16i-W, 18i, 18i-W, 21i, Power Mate i-D, Power Mate i-H]
Fanuc[0i-D, 0i-F, 30i, 31i, 32i, 35i, Power Motion i-A]
Gsk[980, 988]
Gsk[25i]
Gsk[Ethernet, Serial over Ethernet]
Gsk[986 V4.15]
Haas[General, Serial]
Haas[MT-CONNECT]
Heidenhain[TNC640, TNC640 DNC]
Heidenhain[iTNC530 DNC]
Hnc[1.26.02]
Hnc[1.24]
IO Module[ADVANTECH ADAM-6000]
IO Module[USR IO424T]
Jingdiao[JD50]
Kede[GNC62]
Knd[All models]
Lanhao[General]
Lnc[General]
Lynuc[General]
Makino[General]
Mazak[MT-CONNECT]
Mazak[640, Matrix]
Mazak[Smart, Smooth]
Mitsubishi[All models]
Okuma[All models]
Rexroth[OPC UA]
Siemens[802D, 808D, 828D, 840D sl, ONE, OPC UA]
Siemens[810D(winXP), 810D(winNT), 840D(winXP), 840D(winNT)]
Syntec[General]
Mock[General]

✓ Supported; ◐ In development; ✗ Not supported

System [Model] readToolLife readOffsetData writeOffsetData readPlcData writePlcData
Bosunman[BSK Series]
Bosunman[DF Series]
Brother[TC Series]
Brother[S Series]
Brother[A00 Series Serial over Ethernet]
Citizen[Mitsubishi]
Delta[General]
Dmg Mori[730BM]
Dmg Mori[840D]
Dmg Mori[OPC UA]
Fagor[8035M, 8035T, 8040M, 8040T]
Fagor[8055M, 8055T]
Fagor[8060L, 8060M, 8060T, 8065M, 8065T, 8070L, 8070M, 8070T]
Fanuc[0i-B, 0i-C, 15i, 16i, 16i-W, 18i, 18i-W, 21i, Power Mate i-D, Power Mate i-H]
Fanuc[0i-D, 0i-F, 30i, 31i, 32i, 35i, Power Motion i-A]
Gsk[980, 988]
Gsk[25i]
Gsk[Ethernet, Serial over Ethernet]
Gsk[986 V4.15]
Haas[General, Serial]
Haas[MT-CONNECT]
Heidenhain[TNC640, TNC640 DNC]
Heidenhain[iTNC530 DNC]
Hnc[1.26.02]
Hnc[1.24]
IO Module[ADVANTECH ADAM-6000]
IO Module[USR IO424T]
Jingdiao[JD50]
Kede[GNC62]
Knd[All models]
Lanhao[General]
Lnc[General]
Lynuc[General]
Makino[General]
Mazak[MT-CONNECT]
Mazak[640, Matrix]
Mazak[Smart, Smooth]
Mitsubishi[All models]
Okuma[All models]
Rexroth[OPC UA]
Siemens[802D, 808D, 828D, 840D sl, ONE, OPC UA]
Siemens[810D(winXP), 810D(winNT), 840D(winXP), 840D(winNT)]
Syntec[General]
Mock[General]

✓ Supported; ◐ In development; ✗ Not supported

Besides being supported by the control, the tool-life and tool-offset interfaces need target-tool parameters whose form depends on the system. See 5.5.1.14. readOffsetData and 5.5.1.23. readToolLife.

System [Model] readProgramList receiveFileStream sendFileStream deleteFile
Bosunman[BSK Series]
Bosunman[DF Series]
Brother[TC Series]
Brother[S Series]
Brother[A00 Series Serial over Ethernet]
Citizen[Mitsubishi]
Delta[General]
Dmg Mori[730BM]
Dmg Mori[840D]
Dmg Mori[OPC UA]
Fagor[8035M, 8035T, 8040M, 8040T]
Fagor[8055M, 8055T]
Fagor[8060L, 8060M, 8060T, 8065M, 8065T, 8070L, 8070M, 8070T]
Fanuc[0i-B, 0i-C, 15i, 16i, 16i-W, 18i, 18i-W, 21i, Power Mate i-D, Power Mate i-H]
Fanuc[0i-D, 0i-F, 30i, 31i, 32i, 35i, Power Motion i-A]
Gsk[980, 988]
Gsk[25i]
Gsk[Ethernet, Serial over Ethernet]
Gsk[986 V4.15]
Haas[General, Serial]
Haas[MT-CONNECT]
Heidenhain[TNC640, TNC640 DNC]
Heidenhain[iTNC530 DNC]
Hnc[1.26.02]
Hnc[1.24]
IO Module[ADVANTECH ADAM-6000]
IO Module[USR IO424T]
Jingdiao[JD50]
Kede[GNC62]
Knd[All models]
Lanhao[General]
Lnc[General]
Lynuc[General]
Makino[General]
Mazak[MT-CONNECT]
Mazak[640, Matrix]
Mazak[Smart, Smooth]
Mitsubishi[All models]
Okuma[All models]
Rexroth[OPC UA]
Siemens[802D, 808D, 828D, 840D sl, ONE, OPC UA]
Siemens[810D(winXP), 810D(winNT), 840D(winXP), 840D(winNT)]
Syntec[General]
Mock[General]

✓ Supported; ◐ In development; ✗ Not supported

The table above covers machine storage only. With an FTP server, a shared folder, a wireless transfer box or the gateway file server, every interface is available regardless of the machine’s system and model. For each system’s default root path, whether a target directory can be given, and whether subfolder listings are available, see 5.6. File Management APIs.

11.5.2.6. Directories and Program Selection

Section titled “11.5.2.6. Directories and Program Selection”
System [Model] createDir deleteDir selectProgram lockFileByRange
Bosunman[BSK Series]
Bosunman[DF Series]
Brother[TC Series]
Brother[S Series]
Brother[A00 Series Serial over Ethernet]
Citizen[Mitsubishi]
Delta[General]
Dmg Mori[730BM]
Dmg Mori[840D]
Dmg Mori[OPC UA]
Fagor[8035M, 8035T, 8040M, 8040T]
Fagor[8055M, 8055T]
Fagor[8060L, 8060M, 8060T, 8065M, 8065T, 8070L, 8070M, 8070T]
Fanuc[0i-B, 0i-C, 15i, 16i, 16i-W, 18i, 18i-W, 21i, Power Mate i-D, Power Mate i-H]
Fanuc[0i-D, 0i-F, 30i, 31i, 32i, 35i, Power Motion i-A]
Gsk[980, 988]
Gsk[25i]
Gsk[Ethernet, Serial over Ethernet]
Gsk[986 V4.15]
Haas[General, Serial]
Haas[MT-CONNECT]
Heidenhain[TNC640, TNC640 DNC]
Heidenhain[iTNC530 DNC]
Hnc[1.26.02]
Hnc[1.24]
IO Module[ADVANTECH ADAM-6000]
IO Module[USR IO424T]
Jingdiao[JD50]
Kede[GNC62]
Knd[All models]
Lanhao[General]
Lnc[General]
Lynuc[General]
Makino[General]
Mazak[MT-CONNECT]
Mazak[640, Matrix]
Mazak[Smart, Smooth]
Mitsubishi[All models]
Okuma[All models]
Rexroth[OPC UA]
Siemens[802D, 808D, 828D, 840D sl, ONE, OPC UA]
Siemens[810D(winXP), 810D(winNT), 840D(winXP), 840D(winNT)]
Syntec[General]
Mock[General]

✓ Supported; ◐ In development; ✗ Not supported

System [Model] readCNCStatus readAlarm readCount readCurrentToolNumber readTimeData readProgramInfo
Hans[General]
Hans[OPC UA]
Mock[General]

✓ Supported; ◐ In development; ✗ Not supported

System [Model] readProgramBlock readPosition readCurrentProgram readLog
Hans[General]
Hans[OPC UA]
Mock[General]

✓ Supported; ◐ In development; ✗ Not supported

System [Model] readFeed readEnergyConsum readLaserPower readPlcData writePlcData
Hans[General]
Hans[OPC UA]
Mock[General]

✓ Supported; ◐ In development; ✗ Not supported

System [Model] readProgramList receiveFileStream sendFileStream deleteFile
Hans[General]
Hans[OPC UA]
Mock[General]

✓ Supported; ◐ In development; ✗ Not supported

11.5.3.5. Directories and Program Selection

Section titled “11.5.3.5. Directories and Program Selection”
System [Model] createDir deleteDir selectProgram lockFileByRange
Hans[General]
Hans[OPC UA]
Mock[General]

✓ Supported; ◐ In development; ✗ Not supported

System [Model] readCNCStatus readAlarm readCount readProgramInfo
ABB[RobotWare 6.0]
Fanuc[General]
Knd[General]
Kuka[Controller-Side Proxy]
Mock[General]
Efort[ER7BC10]
Estun[General]
Hyundai[General]
Yamaha[RCX]
Yaskawa[YRC1000, YRC High-speed Ethernet]

✓ Supported; ◐ In development; ✗ Not supported

System [Model] readPosition readLog readPlcData writePlcData
ABB[RobotWare 6.0]
Fanuc[General]
Knd[General]
Kuka[Controller-Side Proxy]
Mock[General]
Efort[ER7BC10]
Estun[General]
Hyundai[General]
Yamaha[RCX]
Yaskawa[YRC1000, YRC High-speed Ethernet]

✓ Supported; ◐ In development; ✗ Not supported

System [Model] readCNCStatus readAlarm readCount readPlcData writePlcData
Standard Protocols[All models]
IO Module[ADVANTECH ADAM-6000]
IO Module[USR IO424T]
Jingtuo[JTE-800]
Zhenhuaxing[VCTA-Z5ML]
Allen-Bradley[All models]
Delta[All models]
Keyence[All models]
Melsec[All models]
Omron[All models]
Panasonic[General]
Simatic[All models]
Yongwei[All models]
Mock[General]
Beckhoff[ADS (TwinCAT2, TwinCAT3)]
Cimon[All models]
Fatek[Programming port (serial, serial over Ethernet)]
Fuji[SPB, SPH]
GE[SRTP]
Inovance[AM400, AM400_800, AC800, H3U, XP, H5U, Easy Series]
LSIS[XGB (Cnet, CPU, Fast Enet)]
MegMeet[MC80, MC100, MC200, MC200E, MC280]
Toyopuc[Computer Link (2PORT-EFR module)]
Vigor[VS Series]
Xinje[XC, XD, XL Series]
Yaskawa[Memobus]
Yokogawa[Link]

✓ Supported; ◐ In development; ✗ Not supported

PLCs and other devices are read mainly through the PLC data interfaces. Common values such as machine status, part count and current alarms can be taken from the result of a PLC task instead of the native interface; for the command format see 11.2.1. PLC Data Task.

The same interface does not return the same fields on every system. The tables below list, per data class, the fields that differ between systems: a field not listed here is returned by every system that supports the interface, and 4.2. Data Description explains what it means. A system that does not support the interface is absent from these tables; for that question see 11.5.2. CNC Machine Tools.

A row of ✗ throughout means the system returns only the common fields of that data class. As with the interfaces, the tables describe the field itself; whether data can actually be read also depends on the optional functions and settings of the machine.

The fields below are returned by 5.5.1.12. readCNCCommonStatus - Read Common Machine Status. They appear only on the systems marked here and are not returned on any other machine.

System [Model] Manual Mode Selection Ready Status Alarm Only Status Emergency Set Status Signal Lights
Dmg Mori[OPC UA]
Fanuc[0i-B, 0i-C, 15i, 16i, 16i-W, 18i, 18i-W, 21i, Power Mate i-D, Power Mate i-H] 1
Knd[All models]
Lanhao[General]
Lnc[General]
Mazak[640, Matrix]
Rexroth[OPC UA] 2

✓ Supported; ◐ In development; ✗ Not supported Systems not listed return none of these fields.

Fields: Manual Mode Selection mode2; Ready Status readyStatus; Alarm Only Status alarmOnlyStatus; Emergency Set Status emergencySetStatus; Signal Lights lightColor1, lightStatus1, lightColor2, lightStatus2, lightColor3, lightStatus3, lightColor4, lightStatus4

  1. 15 and 15i only
  2. secondary mode

Each time value is stored as a Min and a Ms field; for the conversion, for how the values are reset and for the Siemens systems that always report 0, see 4.2.24. TimeData: Machine Time Data. There are too many fields for one table, so they run on into a second.

System [Model] Cumulative Power-On Time Current Power-On Time Cumulative Operating Time Current Operating Time Cumulative Cutting Time
Bosunman[BSK Series]
Bosunman[DF Series]
Brother[TC Series]
Brother[S Series]
Brother[A00 Series Serial over Ethernet]
Citizen[Mitsubishi]
Delta[General]
Dmg Mori[840D]
Dmg Mori[OPC UA]
Fagor[8035M, 8035T, 8040M, 8040T]
Fagor[8055M, 8055T]
Fagor[8060L, 8060M, 8060T, 8065M, 8065T, 8070L, 8070M, 8070T]
Fanuc[0i-B, 0i-C, 15i, 16i, 16i-W, 18i, 18i-W, 21i, Power Mate i-D, Power Mate i-H]
Fanuc[0i-D, 0i-F, 30i, 31i, 32i, 35i, Power Motion i-A]
Gsk[980, 988]
Gsk[25i]
Gsk[Ethernet, Serial over Ethernet]
Gsk[986 V4.15]
Haas[General, Serial]
Haas[MT-CONNECT]
Heidenhain[TNC640, TNC640 DNC]
Heidenhain[iTNC530 DNC]
Jingdiao[JD50]
Kede[GNC62]
Knd[All models]
Lanhao[General]
Lnc[General]
Lynuc[General]
Makino[General]
Mazak[MT-CONNECT]
Mazak[Smart, Smooth]
Mitsubishi[All models]
Okuma[All models]
Rexroth[OPC UA]
Siemens[802D, 808D, 828D, 840D sl, ONE, OPC UA]
Siemens[810D(winXP), 810D(winNT), 840D(winXP), 840D(winNT)]
Syntec[General] 1
Mock[General]

✓ Supported; ◐ In development; ✗ Not supported

Fields: Cumulative Power-On Time cumulativePowerOnTimeMin, cumulativePowerOnTimeMs; Current Power-On Time powerOnTimeMin, powerOnTimeMs; Cumulative Operating Time cumulativeOperatingTimeMin, cumulativeOperatingTimeMs; Current Operating Time operatingTimeMin, operatingTimeMs; Cumulative Cutting Time cumulativeCuttingTimeMin, cumulativeCuttingTimeMs

  1. auto run time of the current program
System [Model] Current Cutting Time Last Cycle Time Current Cycle Time Current Workpiece Cutting Time Remaining Cycle Time
Bosunman[BSK Series]
Bosunman[DF Series]
Brother[TC Series]
Brother[S Series]
Brother[A00 Series Serial over Ethernet]
Citizen[Mitsubishi]
Delta[General]
Dmg Mori[840D]
Dmg Mori[OPC UA]
Fagor[8035M, 8035T, 8040M, 8040T]
Fagor[8055M, 8055T]
Fagor[8060L, 8060M, 8060T, 8065M, 8065T, 8070L, 8070M, 8070T]
Fanuc[0i-B, 0i-C, 15i, 16i, 16i-W, 18i, 18i-W, 21i, Power Mate i-D, Power Mate i-H] 1
Fanuc[0i-D, 0i-F, 30i, 31i, 32i, 35i, Power Motion i-A] 1
Gsk[980, 988]
Gsk[25i]
Gsk[Ethernet, Serial over Ethernet]
Gsk[986 V4.15]
Haas[General, Serial]
Haas[MT-CONNECT]
Heidenhain[TNC640, TNC640 DNC]
Heidenhain[iTNC530 DNC]
Jingdiao[JD50]
Kede[GNC62]
Knd[All models]
Lanhao[General]
Lnc[General]
Lynuc[General]
Makino[General] 1
Mazak[MT-CONNECT]
Mazak[Smart, Smooth]
Mitsubishi[All models]
Okuma[All models]
Rexroth[OPC UA]
Siemens[802D, 808D, 828D, 840D sl, ONE, OPC UA]
Siemens[810D(winXP), 810D(winNT), 840D(winXP), 840D(winNT)]
Syntec[General]
Mock[General]

✓ Supported; ◐ In development; ✗ Not supported

Fields: Current Cutting Time cuttingTimeMin, cuttingTimeMs; Last Cycle Time lastCycleTimeMin, lastCycleTimeMs; Current Cycle Time currentCycleTimeMin, currentCycleTimeMs; Current Workpiece Cutting Time currentCuttingTimeMin, currentCuttingTimeMs; Remaining Cycle Time remainingCycleTimeMin, remainingCycleTimeMs

  1. must be reset at the end of the program to clear

Count, time and wear are the three tool life types; the rest are raw data fields returned only by 5.5.1.25. readToolLifeDetails - Read Tool Life Details. Besides being supported by the system, reading tool life needs target-tool parameters whose form depends on the system, see 4.2.25. ToolLife: Tool Life Data.

System [Model] Count Life Time Life Wear Life Tool ID and Overrun Life Exceeded [count] Prewarning Life [time]
Brother[S Series]
Brother[A00 Series Serial over Ethernet]
Citizen[Mitsubishi]
Fanuc[0i-B, 0i-C, 15i, 16i, 16i-W, 18i, 18i-W, 21i, Power Mate i-D, Power Mate i-H]
Fanuc[0i-D, 0i-F, 30i, 31i, 32i, 35i, Power Motion i-A]
Gsk[980, 988]
Gsk[Ethernet, Serial over Ethernet]
Heidenhain[TNC640, TNC640 DNC]
Heidenhain[iTNC530 DNC]
Jingdiao[JD50]
Kede[GNC62]
Lynuc[General]
Makino[General]
Mazak[Smart, Smooth]
Okuma[All models]
Siemens[802D, 808D, 828D, 840D sl, ONE, OPC UA] 1
Siemens[810D(winXP), 810D(winNT), 840D(winXP), 840D(winNT)] 1
Syntec[General]
Mock[General] 2 3 4

✓ Supported; ◐ In development; ✗ Not supported

Fields: Count Life countLimit, currentCount, prewarningCount; Time Life timeLimit, currentTime, prewarningTime; Wear Life wearLimit, currentWear, prewarningWear; Tool ID and Overrun inventoryNum, rawTimeLimit1, rawTimeLimit2, rawOverTime; Life Exceeded [count] rawOverCount; Prewarning Life [time] rawPrewarningTime

  1. user-defined module
  2. ToolNum 1-10
  3. ToolNum 11-20
  4. ToolNum 21-30
  • Models whose support is identical share one row; a model that differs in any single interface is listed separately.
  • Lock program editing (lockFileByRange) is available on the whole Fanuc range and on Makino only.
  • Energy data (readEnergyConsum) is currently supported only by Brother [S Series]; machine log (readLog) and feed (readFeed) only by Mock and Kede [GNC62] respectively. On other systems, read these values through the PLC data interfaces using addresses supplied by the machine builder.
  • Interfaces not listed here are gateway functions of their own (analysis, gateway configuration, history, file-server management) and do not depend on the machine’s system and model.