3. MODBUS Communication

After enabling MODBUS communication and turning on the automatic data collection task for the target machine/group (see the Bivrost Gateway Manual 5.3.1.2. Task Settings and 5.4.1.2. Group Task Settings), the gateway stores the automatic data collection task results in the corresponding register addresses based on the MODBUS protocol. The MODBUS communication address is <Gateway IP>, and the port is 502. To use MODBUS communication, the machine tool must have a slave ID configured (see the Bivrost Gateway Manual 5.3.1.5. Advanced Settings); by default, the last segment of the IP address is used as the slave ID. For example, if the machine tool’s IP is 192.168.100.2, its default slave ID is 2. The slave ID cannot be set to 0 (0 is reserved for the gateway), and the slave IDs of all machine tools connected under the same gateway (default: the last segment of the IP) must be unique from one another; otherwise data identification errors will occur. Users can configure the MODBUS service by following the instructions in the Bivrost Gateway Manual 5.6.2. MODBUS Configuration.

The MODBUS data addresses are as follows:

Address Name Data Type Unit Remarks
400010 Connection status UInt16 - 1-Connected;2-Disconnected;3-Error
400011 Alarm count UInt16 count Current number of alarms
400012 CNC operating status Int16 - Current operating status code, see Operating Status
400013 Cumulative alarm count UInt32 count
400015 Cumulative alarm time UInt32 seconds
400040~400075 Axis 1 to Axis 18 name String(4) - Converted to a 4-byte array (2 register addresses) using the encoding set in the MODBUS configuration.
400100 Machining count UInt32 pieces Machining count obtained from the machine tool’s system
400102 Spindle override Float % Spindle speed override
400104 Actual spindle speed Float same as machine setting
400106 Feed override Float % Feed rate override
400108 Actual feed rate Float same as machine setting
400110~400115 Spindle 1 to Spindle 3 load Float %
400120 Rapid feed override Float %
400122 Commanded feed rate Float same as machine setting
400124 Commanded spindle speed Float same as machine setting
400172 Cumulative power-on time 1 Int32 minutes See 1.2.24. TimeData: Machine Time Data for how the time is calculated. If the value is -2147483648, it indicates the machine tool’s system model does not support this time data.
400174 Cumulative power-on time 2 Int32 milliseconds
400176 Current power-on time 1 Int32 minutes
400178 Current power-on time 2 Int32 milliseconds
400180 Cumulative running time 1 Int32 minutes
400182 Cumulative running time 2 Int32 milliseconds
400184 Current running time 1 Int32 minutes
400186 Current running time 2 Int32 milliseconds
400188 Cumulative machining time 1 Int32 minutes
400190 Cumulative machining time 2 Int32 milliseconds
400192 Current machining time 1 Int32 minutes
400194 Current machining time 2 Int32 milliseconds
400196 Last cycle time 1 Int32 minutes
400198 Last cycle time 2 Int32 milliseconds
400200 Current cycle time 1 Int32 minutes
400202 Current cycle time 2 Int32 milliseconds
400204 Current cutting time 1 Int32 minutes
400206 Current cutting time 2 Int32 milliseconds
400208 Remaining cycle time 1 Int32 minutes
400210 Remaining cycle time 2 Int32 milliseconds
400220 Current tool number String(16) - Converted to a 16-byte array (8 register addresses) using the encoding set in the MODBUS configuration.
400228 Running program name String(32) - Name of the currently executing subprogram
400244 Main program name String(32) - Name of the current main program
400260 Running program block sequence number String(16) - Sequence number of the currently executing subprogram block
400268 Current program block String(70) - Content of the currently running program block
400498 Current machining count UInt32 pieces Machining count within the current monitoring period
400500 Cumulative machining count UInt32 pieces
400502 Shutdown time UInt32 seconds
400504 Emergency stop time UInt32 seconds
400506 Standby time UInt32 seconds
400508 Automatic running time UInt32 seconds
400510 Setup time UInt32 seconds
400512 Machine monitored utilization rate Float %
400520 Cumulative shutdown time UInt32 seconds
400522 Cumulative emergency stop time UInt32 seconds
400524 Cumulative standby time UInt32 seconds
400526 Cumulative automatic running time UInt32 seconds
400528 Cumulative setup time UInt32 seconds
400546 Last takt time UInt32 seconds
400600 Program stack String(128) - Converted to a 128-byte array (64 register addresses) using the encoding set in the MODBUS configuration.
400664 Current tool offset number String(16) -
400900 Preset power Float % Preset power of the laser cutting machine
400902 Actual power Float % Actual power of the laser cutting machine
401100~401135 Axis 1 to Axis 18 load Float %
401136~401171 Axis 1 to Axis 18 machine coordinate Float same as machine setting
401172~401207 Axis 1 to Axis 18 relative coordinate Float same as machine setting
401208~401243 Axis 1 to Axis 18 remaining distance Float same as machine setting
401244~401279 Axis 1 to Axis 18 absolute coordinate Float same as machine setting
401400~401405 Spindle 1 to Spindle 3 cumulative overload time UInt32 milliseconds
401410~401445 Axis 1 to Axis 18 cumulative overload time UInt32 milliseconds
405000 Alarm 1 String(200) - Includes alarm content, time, and level
405100 Alarm 2 String(200) - Same as above
405200 Alarm 3 String(200) - Same as above
405300 Alarm 4 String(200) - Same as above
405400 Alarm 5 String(200) - Same as above
420000~429999 PLC data bits 1 to 10000 UInt16 - PLC task data and external PLC task data, with PLC task data first followed by external PLC task data, arranged in task order. 32-bit data, 64-bit data, and String-type data are converted to UInt16 using the method set in the MODBUS configuration.

Group-related data is stored uniformly under slave ID 0. The data addresses are as follows:

Address Name Data Type Unit Remarks
400100 Group 1 cumulative machining count UInt32 pieces
400102 Current number of shut-down machines in Group 1 Int16 units
400103 Current number of emergency-stopped machines in Group 1 Int16 units
400104 Current number of standby machines in Group 1 Int16 units
400105 Current number of automatically running machines in Group 1 Int16 units
400106 Current number of machines in setup in Group 1 Int16 units
400110 Group 1 shutdown time UInt32 seconds
400112 Group 1 emergency stop time UInt32 seconds
400114 Group 1 standby time UInt32 seconds
400116 Group 1 automatic running time UInt32 seconds
400118 Group 1 setup time UInt32 seconds
400120 Group 1 monitored utilization rate Float %
400130 Group 1 cumulative shutdown time UInt32 seconds
400132 Group 1 cumulative emergency stop time UInt32 seconds
400134 Group 1 cumulative standby time UInt32 seconds
400136 Group 1 cumulative automatic running time UInt32 seconds
400138 Group 1 cumulative setup time UInt32 seconds
400200~400299 Group 2 (corresponding addresses are Group 1’s addresses + 100)
……
401600~401699 Group 16 (corresponding addresses are Group 1’s addresses + 1500)