2.5. Data Read/Write Interface

The data read/write interface lets you read or write machine data, or read machine group data, through the gateway. The data read/write interface is divided into two categories: direct read/write and cached read.

When using direct read/write interfaces, the gateway communicates with the target machine immediately to retrieve or write data.

2.5.1.1. readAlarm - Read Alarm Information

Section titled “2.5.1.1. readAlarm - Read Alarm Information”
GET /api/cnc/readAlarm?machineID=MACHINEID
Request Parameter Type Description
machineID String (Required) Target machine identifier, see 1.1.1. machineID Machine Identifier

Response Example

{
"alarmMsg": [
"警报 1",
"警报 2"],
"alarmLevel": [
"WRN",
"WRN"]
}
Response Parameter Type Description
alarmMsg String[] (Required) The machine’s current alarm content. If there is no alarm, an empty Array is returned.
alarmLevel String[] (Required) Alarm level, corresponding in order to the alarm content. If there is no alarm, an empty Array is returned. See Alarm Level.

2.5.1.2. readCNCStatus - Read Machine Status

Section titled “2.5.1.2. readCNCStatus - Read Machine Status”
GET /api/cnc/readCNCStatus?machineID=MACHINEID&channel=CHANNEL
Request Parameter Type Description
machineID String (Required) Target machine identifier, see 1.1.1. machineID Machine Identifier
channel Int32 Machine channel number. If not specified, it defaults to 0, i.e. the main channel

Response Example

{
"cncStatus": "MANUAL_EDIT",
"alarmStatus": "ALARM",
"alarmLevel": "WRN",
"channel": 2
}
Response Parameter Type Description
cncStatus String (Required) Running status, see Running Status
alarmStatus String (Required) Alarm status, see Alarm Status
alarmLevel String Alarm level. If there are multiple alarms, the highest level among them is taken. If there is no alarm, this field is not returned. See Alarm Level
channel Int32 Machine channel number, present only when channel is included in the request and is not 0

The adjusted running status adjustedStatus, cumulative shutdown time offTime, cumulative standby time waitTime, cumulative emergency-stop time emergencyTime, cumulative auto-run time autoRunTime, cumulative manual-adjustment time ManualTime, and other values derived by the gateway’s post-processing are not currently supported over HTTP. Once an automatic collection task has been enabled, these can be obtained through the interface 2.5.2.1. readTaskData - Read Machine Task Data or 2.5.2.2. batchReadTaskData - Batch Read Machine Task Data, or via MODBUS, MQTT, database, or other means.

2.5.1.3. readCNCStatusDetails - Read Machine Status Details

Section titled “2.5.1.3. readCNCStatusDetails - Read Machine Status Details”

In addition to the same general machine status data returned by 2.5.1.2. readCNCStatus - Read Machine Status, this interface also returns raw, machine-specific data.

GET /api/cnc/readCNCStatusDetails?machineID=MACHINEID&channel=CHANNEL
Request Parameter Type Description
machineID String (Required) Target machine identifier, see 1.1.1. machineID Machine Identifier
channel Int32 Machine channel number. If not specified, it defaults to 0, i.e. the main channel

Response Example

{
"mode": "AUTO_RUN",
"programStatus": "RUNNING",
"emergencyStatus": "NOT_EMG",
"dryRunStatus": "DRY_RUN",
"cncStatus": "AUTO_RUN",
"alarmStatus": "ALARM",
"alarmLevel": "WRN",
"channel": 2
}
Response Parameter Type Description
mode String Operating mode
programStatus String Program status
emergencyStatus String Emergency-stop status, see Emergency-Stop Status
dryRunStatus String Dry-run status, see Dry-Run Status
cncStatus String (Required) Running status, see Running Status
alarmStatus String (Required) Alarm status, see Alarm Status
alarmLevel String Alarm level. If there are multiple alarms, the highest level among them is taken. If there is no alarm, this field is not returned. See Alarm Level
channel Int32 Machine channel number, present only when channel is included in the request and is not 0

The adjusted running status adjustedStatus, cumulative shutdown time offTime, cumulative standby time waitTime, cumulative emergency-stop time emergencyTime, cumulative auto-run time autoRunTime, cumulative manual-adjustment time ManualTime, and other values derived by the gateway’s post-processing are not currently supported over HTTP. Once an automatic collection task has been enabled, these can be obtained through the interface 2.5.2.1. readTaskData - Read Machine Task Data or 2.5.2.2. batchReadTaskData - Batch Read Machine Task Data, or via MODBUS, MQTT, database, or other means.

GET /api/cnc/readCount?machineID=MACHINEID
Request Parameter Type Description
machineID String (Required) Target machine identifier, see 1.1.1. machineID Machine Identifier

Response Example

{
"count": 1052
}
Response Parameter Type Description
count Int32 (Required) Machining count obtained from the machine’s control system

The cumulative machining count cumulativeCount computed by the gateway, and the machining count currentCount for the current monitoring window, are not currently supported over HTTP. Once an automatic collection task has been enabled, these can be obtained through the interface 2.5.2.1. readTaskData - Read Machine Task Data or 2.5.2.2. batchReadTaskData - Batch Read Machine Task Data, or via MODBUS, MQTT, database, or other means.

2.5.1.5. readCurrentToolNumber - Read Current Tool Number

Section titled “2.5.1.5. readCurrentToolNumber - Read Current Tool Number”
GET /api/cnc/readCurrentToolNumber?machineID=MACHINEID&channel=CHANNEL
Request Parameter Type Description
machineID String (Required) Target machine identifier, see 1.1.1. machineID Machine Identifier
channel Int32 Machine channel number. If not specified, it defaults to 0, i.e. the main channel

Response Example

{
"toolNumber": "6",
"toolOffsetNum": "6",
"channel": 2
}
Response Parameter Type Description
toolNumber String (Required) Current tool number
toolOffsetNum String Current tool offset number
channel Int32 Machine channel number, present only when channel is included in the request and is not 0

2.5.1.6. readEnergyConsum - Read Energy Consumption Data

Section titled “2.5.1.6. readEnergyConsum - Read Energy Consumption Data”

Currently supported for some newer Brother machine models and simulated machines only.

GET /api/cnc/readEnergyConsum?machineID=MACHINEID
Request Parameter Type Description
machineID String (Required) Target machine identifier, see 1.1.1. machineID Machine Identifier

Response Example

{
"allServoAxes": 127144.0,
"coolantPump": 41577.0,
"ctsPump": 6507.0,
"chipFlusherPump": 0.0,
"cyclonePump": 0.0,
"system24V": 46270.0,
"ncControl": 10099.0,
"lcdBacklight": 2884.0,
"chipConveyor": 0.0,
"screwConveyor": 0.0,
"autoLubrication": 239.0,
"spindleCoolingFan": 7212.0,
"servoControl": 23806.0
}
Response Parameter Type Description
allServoAxes Double Energy consumption of all servo axes [Wh]
coolantPump Double Coolant pump energy consumption [Wh]
ctsPump Double CTS pump energy consumption [Wh]
chipFlusherPump Double Chip flusher pump energy consumption [Wh]
cyclonePump Double Cyclone filter pump energy consumption [Wh]
system24V Double 24V system energy consumption [Wh]
ncControl Double NC control energy consumption [Wh]
lcdBacklight Double LCD backlight energy consumption [Wh]
chipConveyor Double Chip conveyor energy consumption [Wh]
screwConveyor Double Screw conveyor energy consumption [Wh]
autoLubrication Double Automatic lubrication device (or automatic greasing device) energy consumption [Wh]
spindleCoolingFan Double Spindle cooling fan energy consumption [Wh]
servoControl Double Servo control energy consumption [Wh]

Laser cutting/welding machines only.

GET /api/cnc/readFeed?machineID=MACHINEID&channel=CHANNEL
Request Parameter Type Description
machineID String (Required) Target machine identifier, see 1.1.1. machineID Machine Identifier
channel Int32 Machine channel number. If not specified, it defaults to 0, i.e. the main channel

Response Example

{
"overFeed": 100.0,
"actFeed": 80.0,
"cmdFeed": 80.0,
"overRapid": 100.0,
"channel": 2
}
Response Parameter Type Description
overFeed Float Feed override [%]
actFeed Float Actual feed rate
cmdFeed Float Commanded feed rate
overRapid Float Rapid traverse override [%]
channel Int32 Machine channel number, present only when channel is included in the request and is not 0

2.5.1.8. readFeedAndSpindle - Read Feed and Spindle Speed Data

Section titled “2.5.1.8. readFeedAndSpindle - Read Feed and Spindle Speed Data”

CNC machines only.

GET /api/cnc/readFeedAndSpindle?machineID=MACHINEID&channel=CHANNEL
Request Parameter Type Description
machineID String (Required) Target machine identifier, see 1.1.1. machineID Machine Identifier
channel Int32 Machine channel number. If not specified, it defaults to 0, i.e. the main channel

Response Example

{
"overSpindle": 150.0,
"actSpindle": 3000.0,
"cmdSpindle": 3000.0,
"overFeed": 100.0,
"actFeed": 80.0,
"cmdFeed": 80.0,
"overRapid": 100.0,
"channel": 2
}
Response Parameter Type Description
overSpindle Float Spindle speed override [%]
actSpindle Float Actual spindle speed
cmdSpindle Float Commanded spindle speed
overFeed Float Feed override [%]
actFeed Float Actual feed rate
cmdFeed Float Commanded feed rate
overRapid Float Rapid traverse override [%]
channel Int32 Machine channel number, present only when channel is included in the request and is not 0

When there are multiple spindles, only the speed data of the first spindle is returned.

2.5.1.9. readLaserPower - Read Laser Power

Section titled “2.5.1.9. readLaserPower - Read Laser Power”

Laser cutting/welding machines only.

GET /api/cnc/readLaserPower?machineID=MACHINEID
Request Parameter Type Description
machineID String (Required) Target machine identifier, see 1.1.1. machineID Machine Identifier

Response Example

{
"preset": 100.0,
"actual": 100.0
}
Response Parameter Type Description
preset Float Preset power [%]
actual Float Actual power [%]

CNC machines only.

GET /api/cnc/readLoad?machineID=MACHINEID&channel=CHANNEL
Request Parameter Type Description
machineID String (Required) Target machine identifier, see 1.1.1. machineID Machine Identifier
channel Int32 Machine channel number. If not specified, it defaults to 0, i.e. the main channel

Response Example

{
"spindleLoad": [
100.0,
0.0],
"axialLoad": [
50.1,
12.4,
0.0],
"channel": 2
}
Response Parameter Type Description
spindleLoad Float[] Spindle load [%]
axialLoad Float[] Servo axis load [%]
channel Int32 Machine channel number, present only when channel is included in the request and is not 0

When there are multiple spindles, the entries in the spindle load data correspond in order to the first spindle, second spindle, and so on. The servo axis load values correspond one-to-one, in order, with the axisName values returned by 2.5.1.15. readPosition - Read Position Data.

Currently supported for Fanuc robots, ABB robots, and simulated machines.

GET /api/cnc/readLog?machineID=MACHINEID
Request Parameter Type Description
machineID String (Required) Target machine identifier, see 1.1.1. machineID Machine Identifier
type String Type, possible values: Alarm (alarm log), Operation (operation log), Default (default), defaults to Default. ABB robots support Operation; Fanuc robots support Alarm; simulated machines support all types, and Default is equivalent to Operation.
count Int32 Number of log entries. Retrieves the specified number of most recent log entries; defaults to 0, meaning all logs are retrieved.

Response Example (ABB robot, Operation)

{
"msgs": [
"{\"SeqNo\":\"79\",\"Type\":\"I \",\"Code\":\"10011\",\"Title\":\" 电机上电(ON) 状态\",\"Date\":\"2025-04-02 T 10:54:40\",\"Description\":\"系统处于电机上电 (ON) 状态。\",\"Args\":[]}",
"{\"SeqNo\":\"78\",\"Type\":\"I \",\"Code\":\"10010\",\"Title\":\" 电机下电 (OFF) 状态\",\"Date\":\"2025-04-02 T 10:54:39\",\"Description\":\"系统处于电机下电 (OFF) 状态。从手动模式切换至自动模式,或者程序执行过程中电机上电 (ON) 电路被打开后,系统就会进入此状态。\",\"Args\":[]}"]
}

Response Example (Fanuc robot, Alarm)

{
"msgs": [
"{\"AlarmID\":24,\"AlarmNumber\":212,\"CauseAlarmID\":0,\"CauseAlarmNumber\":0,\"Severity\":38,\"Time\":\"2025-06-26T04:04:46\",\"AlarmMessage\":\"SYST-212 需要应用 DCS 参数\",\"CauseAlarmMessage\":\"\",\"SeverityMessage\":\"STOP.G\"}",
"{\"AlarmID\":0,\"AlarmNumber\":0,\"CauseAlarmID\":0,\"CauseAlarmNumber\":0,\"Severity\":0,\"Time\":\"2025-06-26T04:04:46\",\"AlarmMessage\":\"重置\",\"CauseAlarmMessage\":\"\",\"SeverityMessage\":\"\"}"]
}

Response Example (simulated machine, Operation)

{
"msgs": [
"2025-07-07 13:24:45 Status: WAIT",
"2025-07-07 13:24:45 Machine power on"]
}

Response Example (simulated machine, Alarm)

{
"msgs": [
"2025-07-07 13:25:05 Alarm: 102 ALARM 2, 13:25",
"2025-07-07 13:25:05 Alarm: 101 ALARM 1, 13:25"
]
}
Response Parameter Type Description
msgs String[] (Required) Log content. Note: the log content format differs between machine types.