1.3. Variable Definitions

Running status:

Status Code Return String Running Status Description
0 OFF Powered off or offline
1 EMERGENCY Emergency stop Emergency stop button pressed
2 WAIT Standby: general standby 1. In Automatic (including Remote Automatic) mode, the program is not running and the specific status cannot be identified; 2. Unrecognized operating mode
3 WAIT_HOLD Standby: program paused Program paused state in Automatic (including Remote Automatic) mode
4 WAIT_STOP Standby: program stopped Program stopped state in Automatic (including Remote Automatic) mode
5 WAIT_IDLE Standby: idle Idle or ready state in Automatic mode or Remote Automatic mode
10 AUTO_RUN Automatic running Program running in Automatic mode
11 AUTO_RUN_REMOTE Remote automatic running Program running in Remote Automatic mode
20 MANUAL Setup: general setup Non-automatic state; the specific setup status cannot be identified
21 MANUAL_EDIT Setup: program editing
22 MANUAL_MDI Setup: manual data input
23 MANUAL_HANDLE Setup: manual handwheel feed
24 MANUAL_HANDLE_TCH Setup: manual handwheel feed teaching
25 MANUAL_JOG Setup: manual jog feed
26 MANUAL_JOG_TCH Setup: manual jog feed teaching
27 MANUAL_INC Setup: incremental feed/step
28 MANUAL_REF Setup: return to reference point
29 MANUAL_REMOTE Setup: remote
30 MANUAL_MSTR Setup: tool retract/repositioning
31 MANUAL_DRY_RUN Setup: dry run
32 MANUAL_RAPID Setup: rapid positioning
33 MANUAL_SINGLE_BLOCK Setup: single block operation
34 MANUAL_MDI_RUN Setup: running program in MDI mode
35 MANUAL_HOLD Setup: paused Paused in non-automatic (including remote automatic) mode
Return String Alarm Status
ALARM Alarm present
NO_ALARM No alarm

1.3.1.3. EmergencyStatus: Emergency Stop Status

Section titled “1.3.1.3. EmergencyStatus: Emergency Stop Status”
Return String Emergency Stop Status
EMG Emergency stop
NOT_EMG Not emergency stop
Return String Dry Run Status
DRY_RUN Dry run
NOT_DRY_RUN Not dry run

Alarm levels, in descending order of priority, are Error (ERR), Warning (WRN), and Message (INF). Users can refer to the Bivrost Gateway Manual 5.5.7. Alarm Monitor Settings to set alarm levels by keyword and filter out alarms below the minimum alarm level. Alarms with no configured level default to the WRN (Warning) level.

Return String Alarm Level
ERR Error
WRN Warning
INF Message

1.3.3.1. ServiceRunningStatus: Service Running Status

Section titled “1.3.3.1. ServiceRunningStatus: Service Running Status”

Running status of each gateway service.

Return Int32 Running Status
0 Disabled
1 Initiated
2 Ready
3 Running
4 Delayed
5 Error