2.9.3. Machine Configuration Interface

The machine configuration interface is used to retrieve, add, modify, or delete machine configurations. For more information on machine configuration, see the Bivrost Gateway Manual 5.3. Machine Configuration. All configuration parameters for a machine are listed in the table below; these parameters are used as request or response parameters in the machine configuration interface.

Parameter Type Description
id Int32 Database identifier. See 1.1.4. ID Database Identifier
machineType String Machine type. See machineType Machine Type Mapping
system String System. The value range corresponds to the System options in the Add Machine window under the English UI language.
model String Model. The value range corresponds to the Model options in the Add Machine window under the English UI language.
name String Machine name
machineID String Machine identifier. See 1.1.1. machineID Machine Identifier
slaveID Int32 Slave identifier. See 1.1.3. slaveID Slave Identifier
ip String IP address
port Int32 Port number. 0 represents each device’s default port.
isActive Bool Activation status. true = active, false = inactive
useDefaultMachineID Bool Use default machine identifier
useDefaultSlaveID Bool Use default slave identifier
customAttributes String Custom attributes. Example: {"attribute": value,…}
username String Username. Required for some devices.
permission String Permission. Only required for Delta CNC systems. Range: NORMAL, USER_1, USER_2, MACHIN, SYSTEM. Default is NORMAL.
password String Password. Required for some devices.
version String Version. Required for some devices.
connectionMode String Connection mode. Required for some devices.
encoding String Encoding, e.g. ASCII, UTF-8, GBK, etc. Default is “default” (auto-detect).
language String Alarm language. Only required for Siemens systems; currently supports English and Chinese. Default is Chinese.
numberOfTasks Int32 Number of enabled tasks. Read-only.
taskAlarm Bool Alarm information task. true = enabled, false = disabled.
taskAlarmPrecond String Precondition for the alarm information task. Not returned if not set.
taskAlarmEnableCustomAlarm Bool Custom alarm. true = enabled, false = disabled. When enabled, the custom alarm replaces the default alarm. Custom alarm task execution logic: first check the alarm status; if there is an alarm, retrieve the alarm content. If this tag is empty, skip checking the alarm status and retrieve the alarm content directly, determining the alarm status by whether alarm content is present.
taskAlarmCustomAlarmAlarmStatusTag String Custom alarm alarmStatus tag. Enter the corresponding PLC data task result tag.
taskAlarmCustomAlarmAlarmMsgTag String Custom alarm alarmMsg tag. Enter the corresponding PLC data task result tag.
taskMachineStatus Bool Machine status task. true = enabled, false = disabled.
taskChannelMachineStatus String Target channel for the machine status task, e.g. “0;1-3”.
taskMachineStatusPrecond String Precondition for the machine status task. Not returned if not set.
taskMachineStatusEnableAdjustedManual Bool Machine status task setup-status correction. true = enabled, false = disabled.
taskMachineStatusMaxManualPauseTime Int32 Maximum setup-pause time for the machine status task (seconds).
taskMachineStatusEnableStatusConversion Bool Machine status task status conversion. true = enabled, false = disabled.
taskMachineStatusStatusConversionSettings String Status to convert to when the machine status task’s condition is met.
taskMachineStatusEnableCustomStatus Bool Custom machine status task. true = enabled, false = disabled. When enabled, the custom status replaces the default status.
taskMachineStatusCustomStatusCNCStatusTag String Custom status cncStatus tag. Enter the corresponding PLC data task result tag.
taskMachineStatusCustomStatusAlarmStatusTag String Custom status alarmStatus tag. Enter the corresponding PLC data task result tag.
taskCount Bool Machining count task. true = enabled, false = disabled.
taskCountPrecond String Precondition for the machining count task. Not returned if not set.
taskCountEnableCustomCount Bool Custom machining count task. true = enabled, false = disabled. When enabled, the custom machining count replaces the default machining count.
taskCountCustomCountCountTag String Custom machining count tag. Enter the corresponding PLC data task result tag.
taskCurrentToolNo Bool Current tool number task. true = enabled, false = disabled.
taskChannelCurrentToolNo String Target channel for the current tool number task, e.g. “0;1-3”.
taskCurrentToolNoPrecond String Precondition for the current tool number task. Not returned if not set.
taskEnergyConsumption Bool Energy consumption task. true = enabled, false = disabled.
taskEnergyConsumptionPrecond String Precondition for the energy consumption task. Not returned if not set.
taskFeed Bool Feed rate task. true = enabled, false = disabled.
taskChannelFeed String Target channel for the feed rate task, e.g. “0;1-3”.
taskFeedPrecond String Precondition for the feed rate task. Not returned if not set.
taskFeedAndSpindle Bool Feed rate and spindle speed task. true = enabled, false = disabled.
taskChannelFeedAndSpindle String Target channel for the feed rate and spindle speed task, e.g. “0;1-3”.
taskFeedAndSpindlePrecond String Precondition for the feed rate and spindle speed task. Not returned if not set.
taskLaserPower Bool Laser power task. true = enabled, false = disabled.
taskFeedPrecond String Precondition for the laser power task. Not returned if not set.
taskLoad Bool Load data task. true = enabled, false = disabled.
taskChannelLoad String Target channel for the load data task, e.g. “0;1-3”.
taskLoadPrecond String Precondition for the load data task. Not returned if not set.
taskLogHistory Bool Log history task. true = enabled, false = disabled.
taskLogHistoryPrecond String Precondition for the log history task. Not returned if not set.
taskOverLoad Bool Overload monitoring task. true = enabled, false = disabled.
taskChannelOverLoad String Target channel for the overload monitoring task, e.g. “0;1-3”.
taskOverLoadPrecond String Precondition for the overload monitoring task. Not returned if not set.
taskPlcData Bool PLC data task. true = enabled, false = disabled.
taskPlcDataSettings String PLC data task settings
taskPosition Bool Position data task. true = enabled, false = disabled.
taskChannelPosition String Target channel for the position data task, e.g. “0;1-3”.
taskPositionPrecond String Precondition for the position data task. Not returned if not set.
taskCurrentProgramBlock Bool Current program block task. true = enabled, false = disabled.
taskCurrentProgramBlockPrecond String Precondition for the current program block task. Not returned if not set.
taskProgramInfo Bool Machining program task. true = enabled, false = disabled.
taskChannelProgramInfo String Target channel for the machining program task, e.g. “0;1-3”.
taskProgramInfoPrecond String Precondition for the machining program task. Not returned if not set.
taskMachineTimeData Bool Machine time task. true = enabled, false = disabled.
taskMachineTimeDataPrecond String Precondition for the machine time task. Not returned if not set.
taskToolLife Bool Tool life task. true = enabled, false = disabled.
taskToolLifePrecond String Precondition for the tool life task. Not returned if not set.
taskToolLifeGroupNumIndex String Target tool for the tool life task, in {tool group number.index within group} format.
taskToolLifeIndex String Target tool for the tool life task, in {index} format.
taskToolLifeToolNum String Target tool for the tool life task, in {tool number} format.
taskToolLifeToolNumOffsetNum String Target tool for the tool life task, in {tool number.offset number} format.
taskToolOffset Bool Tool offset task. true = enabled, false = disabled.
taskChannelToolOffset String Target channel for the tool offset task, e.g. “0;1-3”.
taskToolOffsetPrecond String Precondition for the tool offset task. Not returned if not set.
taskToolOffsetToolNum String Target tool for the tool offset task, in {tool number} format.
taskToolOffsetOffsetNum String Target tool for the tool offset task, in {offset number} format.
taskToolOffsetToolNumOffsetNum String Target tool for the tool offset task, in {tool number.offset number} format.
taskAlarmHistory Bool Alarm history task. true = enabled, false = disabled.
taskAlarmHistoryPrecond String Precondition for the alarm history task. Not returned if not set.
taskCycleData Bool Cycle time data task. true = enabled, false = disabled.
taskCycleDataPrecond String Precondition for the cycle time data task. Not returned if not set.
taskOEE Bool OEE monitoring task. true = enabled, false = disabled.
taskOEEPrecond String Precondition for the OEE monitoring task. Not returned if not set.
taskExternalPlcDataSettings String External PLC task settings
parallelProcessing Int Number of parallel task processes
fileServerType String File server type (program transfer). Possible values: Machine Memory, Shared Folder, Shared Folder (Win XP), FTP Server, Wireless Disk, Gateway File Server.
fileServerAddress String Server address (program transfer).
fileServerPort Int32 Custom port (program transfer).
fileServerUsername String Username (program transfer).
fileServerPassword String Password (program transfer).
fileServerUCode String U code (program transfer).
fileServerRootDir String Root directory (program transfer).
modbusSlaveID Int32 Slave ID (general). Required for MODBUS communication. Default is 1.
modbusByteOrder4 String 32-bit format. Required for MODBUS communication. Range: DCBA, BADC, ABCD, CDAB.
modbusByteOrder8 String 64-bit format. Required for MODBUS communication. Range: HGFEDCBA, BADCFEHG, ABCDEFGH, GHEFCDAB.
modbusPLCAddress Bool Use PLC address. Required for MODBUS communication. true = enabled, false = disabled. When enabled, the target address is offset by +1.
modbusReverseString Bool Reverse string. Required for MODBUS communication. true = enabled, false = disabled.
plcRack Int32 Rack number. Required for some devices.
plcSlot Int32 Slot number. Required for some devices.
plcStation Int32 Station number. Required for some devices.
plcCommunicationFormat String Communication format. Required for some devices.
plcCommunicationType String Communication type. Required for some devices.
plcTsapSystemOfNumeration String TSAP numeral system. Required for some devices. Range: Decimal, Hexadecimal.
plcLocalTsap String Local TSAP. Required for some devices.
plcRemoteTsap String Remote TSAP. Required for some devices.
plcRouter String Router. Required for some devices.
plcDA2 Int32 DA2. Required for some devices.
plcSA1 Int32 SA1. Required for some devices.
plcSA2 Int32 SA2. Required for some devices.
plcGCT Int32 GCT. Required for some devices.
plcSID Int32 SID. Required for some devices.
plcSumCheck Bool Checksum. Required for some devices. true = enabled, false = disabled.
plcReverseString Bool Reverse string. Required for some devices. true = enabled, false = disabled.
plcAutoRunValue Int32 Auto-run status value. Required for some devices. Possible values: 1, 2. Default is 1.
plcUseStation Bool Use station number. Required for some devices. true = enabled, false = disabled.

The types currently supported by machineType are listed in the table below.

machineType Machine Type
CNC CNC
LASER Laser cutting machine
PLC PLC
ROBOT Robot

2.9.3.1. machine Get Machine Configuration

Section titled “2.9.3.1. machine Get Machine Configuration”
GET /api/config/machine?ID=ID&machineID=MACHINEID
Request Parameter Type Description
id Int32 Database identifier. See 1.1.4. ID Database Identifier
machineID String Target machine identifier. See 1.1.1. machineID Machine Identifier. If both ID and machineID are provided, machineID is ignored.

Response example

{
"id": 1,
"machineType": "CNC",
"system": "Mock",
"model": "General",
"name": "演示 1",
"useDefaultMachineID": true,
"machineID": "1",
"useDefaultSlaveID": true,
"slaveID": 1,
"customAttributes": "",
"encoding": "Default",
"ip": "127.0.0.1",
"port": 0,
"isActive": true,
"numberOfTasks": 20,
"taskAlarm": true,
"taskAlarmEnableCustomAlarm": false,
"taskMachineStatus": true,
"taskChannelMachineStatus": "0",
"taskMachineStatusEnableAdjustedManual": false,
"taskMachineStatusMaxManualPauseTime": 600,
"taskMachineStatusEnableStatusConversion": false,
"taskMachineStatusEnableCustomStatus": false,
"taskCount": true,
"taskCountEnableCustomCount": false,
"taskCountPrecond": "CNCStatus_cncStatus = \"AUTO_RUN\" and Load_spindleLoad[0] > 50",
"taskCurrentToolNo": true,
"taskChannelCurrentToolNo": "0",
"taskEnergyConsumption": true,
"taskFeedAndSpindle": true,
"taskChannelFeedAndSpindle": "0",
"taskLoad": true,
"taskChannelLoad": "0",
"taskLogHistory": true,
"taskOverLoad": true,
"taskChannelOverLoad": "0",
"taskPlcData": true,
"taskPlcDataSettings": "R,0,10,Int16;Y,0,3,Bit0",
"taskPosition": true,
"taskChannelPosition": "0",
"taskCurrentProgramBlock": true,
"taskChannelCurrentProgramBlock": "0",
"taskProgramInfo": true,
"taskChannelProgramInfo": "0",
"taskMachineTimeData": true,
"taskToolLife": true,
"taskToolOffset": true,
"taskChannelToolOffset": "0",
"taskToolOffsetToolNumOffsetNum": "1.2;3-5.1;7-9.1-3",
"taskAlarmHistory": true,
"taskCycleData": true,
"taskOEE": true,
"parallelProcessing": 1,
"fileServerType": "Machine Memory",
"fileServerRootDir": ""
}

See Machine Configuration Parameters for the response parameters.

2.9.3.2. machines Get All Machine Configurations

Section titled “2.9.3.2. machines Get All Machine Configurations”

This interface has no request parameters.

GET /api/config/machines

Response example

[
{
"id": 1,
"machineType": "CNC",
"system": "Mock",
"model": "General",
"name": "演示 1",
"useDefaultMachineID": true,
"machineID": "1",
"useDefaultSlaveID": true,
"slaveID": 1,
"customAttributes": "",
"encoding": "Default",
"ip": "127.0.0.1",
"port": 0,
"isActive": true,
"numberOfTasks": 20,
"taskAlarm": true,
"taskAlarmEnableCustomAlarm": false,
"taskMachineStatus": true,
"taskChannelMachineStatus": "0",
"taskMachineStatusEnableAdjustedManual": false,
"taskMachineStatusMaxManualPauseTime": 600,
"taskMachineStatusEnableStatusConversion": false,
"taskMachineStatusEnableCustomStatus": false,
"taskCount": true,
"taskCountEnableCustomCount": false,
"taskCountPrecond": "CNCStatus_cncStatus = \"AUTO_RUN\" and Load_spindleLoad[0] > 50",
"taskCurrentToolNo": true,
"taskChannelCurrentToolNo": "0",
"taskEnergyConsumption": true,
"taskFeedAndSpindle": true,
"taskChannelFeedAndSpindle": "0",
"taskLoad": true,
"taskChannelLoad": "0",
"taskLogHistory": true,
"taskOverLoad": true,
"taskChannelOverLoad": "0",
"taskPlcData": true,
"taskPlcDataSettings": "R,0,10,Int16;Y,0,3,Bit0",
"taskPosition": true,
"taskChannelPosition": "0",
"taskCurrentProgramBlock": true,
"taskChannelCurrentProgramBlock": "0",
"taskProgramInfo": true,
"taskChannelProgramInfo": "0",
"taskMachineTimeData": true,
"taskToolLife": true,
"taskToolOffset": true,
"taskChannelToolOffset": "0",
"taskToolOffsetToolNumOffsetNum": "1.2;3-5.1;7-9.1-3",
"taskAlarmHistory": true,
"taskCycleData": true,
"taskOEE": true,
"parallelProcessing": 1,
"fileServerType": "Machine Memory",
"fileServerRootDir": ""
},
{
"id": 2,
"machineType": "PLC",
"system": "Standard Protocols",
"model": "Modbus TCP",
"name": "2",
"useDefaultMachineID": true,
"machineID": "2",
"useDefaultSlaveID": true,
"slaveID": 2,
"customAttributes": "",
"encoding": "Default",
"ip": "127.0.0.2",
"port": 0,
"isActive": true,
"numberOfTasks": 2,
"taskAlarm": false,
"taskAlarmEnableCustomAlarm": false,
"taskMachineStatus": false,
"taskChannelMachineStatus": "0",
"taskMachineStatusEnableAdjustedManual": false,
"taskMachineStatusMaxManualPauseTime": 600,
"taskMachineStatusEnableStatusConversion": false,
"taskMachineStatusEnableCustomStatus": false,
"taskCount": false,
"taskCountEnableCustomCount": false,
"taskPlcData": true,
"taskPlcDataSettings": "4x,100,2,Int32;0x,100,10,Bit0;",
"taskAlarmHistory": false,
"taskOEE": false,
"parallelProcessing": 1,
"modbusSlaveID": 1,
"modbusByteOrder4": "DCBA",
"modbusByteOrder8": "HGFEDCBA",
"modbusPLCAddress": false,
"modbusReverseString": false
}
]

See Machine Configuration Parameters for the response parameters.

2.9.3.3. create-machine Add Machine Configuration

Section titled “2.9.3.3. create-machine Add Machine Configuration”
POST /api/config/create-machine

Request body example

{
"machineType": "PLC",
"system": "Standard Protocols",
"model": "Modbus TCP",
"name": "150",
"useDefaultMachineID": false,
"machineID": "M150",
"useDefaultSlaveID": true,
"ip": "127.0.0.150",
"isActive": true,
"taskPlcData": true,
"taskPlcDataSettings": "4x,100,2,Int32;0x,100,10,Bit0;"
}

See Machine Configuration Parameters for the request parameters. Note that the database identifier id does not need to be set in the request body; it is automatically assigned by the gateway and appears in the response body after successful creation.

Response example

{
"id": 21,
"machineType": "PLC",
"system": "Standard Protocols",
"model": "Modbus TCP",
"name": "150",
"useDefaultMachineID": false,
"machineID": "M150",
"useDefaultSlaveID": true,
"slaveID": 150,
"customAttributes": "",
"encoding": "Default",
"ip": "127.0.0.150",
"port": 0,
"isActive": true,
"numberOfTasks": 2,
"taskAlarm": false,
"taskAlarmEnableCustomAlarm": false,
"taskMachineStatus": false,
"taskChannelMachineStatus": "0",
"taskMachineStatusEnableAdjustedManual": false,
"taskMachineStatusMaxManualPauseTime": 600,
"taskMachineStatusEnableStatusConversion": false,
"taskMachineStatusEnableCustomStatus": false,
"taskCount": false,
"taskCountEnableCustomCount": false,
"taskPlcData": true,
"taskPlcDataSettings": "4x,100,2,Int32;0x,100,10,Bit0;",
"taskAlarmHistory": false,
"taskOEE": false,
"parallelProcessing": 1,
"modbusSlaveID": 1,
"modbusByteOrder4": "DCBA",
"modbusByteOrder8": "HGFEDCBA",
"modbusPLCAddress": false,
"modbusReverseString": false
}

See Machine Configuration Parameters for the response parameters.

2.9.3.4. update-machine Modify Machine Configuration

Section titled “2.9.3.4. update-machine Modify Machine Configuration”

Modifies the configuration of the specified machine and returns the updated machine configuration.

POST /api/config/update-machine

Request body example

{
"id": 21,
"name": "newName",
"useDefaultMachineID": false,
"machineID": "newMachineID",
"useDefaultSlaveID": false,
"slaveID": 192,
"ip": "127.0.0.192",
"port": 6000,
"isActive": false,
"taskPlcData": false
}

See Machine Configuration Parameters for the request parameters. Note: this interface uses id as the unique identifier, so the database identifier id must be set in the request body. The machine identifier machineID can be modified through this interface.

Response example

{
"id": 21,
"machineType": "PLC",
"system": "Standard Protocols",
"model": "Modbus TCP",
"name": "newName",
"useDefaultMachineID": false,
"machineID": "newMachineID",
"useDefaultSlaveID": true,
"slaveID": 192,
"customAttributes": "",
"encoding": "Default",
"ip": "127.0.0.150",
"port": 6000,
"isActive": false,
"numberOfTasks": 0,
"taskAlarm": false,
"taskAlarmEnableCustomAlarm": false,
"taskMachineStatus": false,
"taskChannelMachineStatus": "0",
"taskMachineStatusEnableAdjustedManual": false,
"taskMachineStatusMaxManualPauseTime": 600,
"taskMachineStatusEnableStatusConversion": false,
"taskMachineStatusEnableCustomStatus": false,
"taskCount": false,
"taskCountEnableCustomCount": false,
"taskPlcData": false,
"taskPlcDataSettings": "4x,100,2,Int32;0x,100,10,Bit0;",
"taskAlarmHistory": false,
"taskOEE": false,
"parallelProcessing": 1,
"modbusSlaveID": 1,
"modbusByteOrder4": "DCBA",
"modbusByteOrder8": "HGFEDCBA",
"modbusPLCAddress": false,
"modbusReverseString": false
}

See Machine Configuration Parameters for the response parameters.

2.9.3.5. delete-machine Delete Machine Configuration

Section titled “2.9.3.5. delete-machine Delete Machine Configuration”
GET /api/config/delete-machine?ID=ID&machineID=MACHINEID
Request Parameter Type Description
id Int32 Database identifier. See 1.1.4. ID Database Identifier
machineID String Target machine identifier. See 1.1.1. machineID Machine Identifier. If both ID and machineID are provided, machineID is ignored.

Response example

{
"errorCode": 0,
"errorMsg": "Success"
}
Response Parameter Type Description
errorCode Int32 (Required) Error code. 0 indicates success.
errorMsg String (Required) Error message

2.9.3.6. batch-delete-machines Batch Delete Machine Configurations

Section titled “2.9.3.6. batch-delete-machines Batch Delete Machine Configurations”

This interface is the batch version of 2.9.3.5. delete-machine Delete Machine Configuration. By including database IDs in the request body, multiple machines can be deleted at once.

POST /api/config/batch-delete-machines

Request body example application/json

{
"ids": [
2,
3,
4
]
}
Request Parameter Type Description
ids Int32[] (Required) Database identifiers. See 1.1.4. ID Database Identifier

Response example

{
"deleted": 3
}

The response body reflects the execution result corresponding to the request, in the order given in the request body.

Response Parameter Type Description
deleted Int32 (Required) Number of machines deleted